Analisis Kebutuhan Debit Air Di Gedung C RSUD Kota Bukittinggi

  • Mela Melarizki Rizki Umsb
  • Muchlisi Nalahuddin Teknik Mesin, Fakultas Teknik, Universitas Muhammadiayah Sumatera Barat
  • Riza Muharni Teknik Mesin, Fakultas Teknik, Universitas Muhammadiayah Sumatera Barat
Keywords: Building, Pump, Tank

Abstract

In the Bukittinggi City Hospital building which has 6 floors, there is a water pump and a reservoir used to supply clean water for daily needs. Based on the reality in the field where there is no secondary data to determine the type of pump and reservoir. The purpose of this analysis is to obtain clean water discharge requirements, obtain the type of pump and ensure that the reservoir used for building C RSUD Kota Bukittinggi is in accordance with the type of pipe and reservoir installed in building C, floor 6. By using field studies and interviews and applying the formulas related to pump calculations. In determining the type of pump to be used in the building, it includes the required water discharge, determining the capacity of the components to be used such as pipe diameter, water tank capacity on the ground floor and roof of the building and the total head on the pipe. Based on the calculation results, the required water discharge is 0.08333 m 3 /min, the upper reservoir has a capacity of 150,000 liters, the bottom reservoir is 5,000 liters and the Hot that occurs is 18.429 m. Then the required pump specifications are 40 x 32B2 -51.5 Grundfos CM 10-3. The pump specifications are not much different from those that have been applied in the field.

References

Anis,S.,& Karnowo.(2008). Dasar Pompa. In Buku Ajar Candra, R. (2018). Perancangan Pompa Sentrifugal Dan Diameter Luar Impeller Untuk Kebutuhan Air Kapasitas 60 LPM di gedung F dan D Universitas Muhammadiyah Tanggerang.

Muliawan, A., & Yani, A. (2018). Analisa Head Mayor dan Minor Pompa Chiller dengan Bukaan Katup Instalasi Pompa Tunggal.

Tukiman, Santoso, P., & Satmoko, A. (2013). Perhitungan dan pemilihan pompa pada instalasi pengolahan air bebas mineral iradiator mamma kapasitas 200 Kci.

Ubaedilah, U. (2017). Analisa Kebutuhan Jenis Dan Spesifikasi Pompa Untuk Suplai Air Bersih Di Gedung Kantin Berlantai 3 PT Astra Daihatsu Motor.

Tahara, Haruo., dan sularso. 2000. Pompa dan kompresor. Jakarta: PT. Pradaya Paramita

Dietzel, Fritz. 1996. Turbin pompa dan kompresor. Aih BahasaDakso Sriyono. Jakarta: Erlangga.

ASTM A53 Grade A dan B Standart Pipe Schedule 40.

Selecting Centrifugal Pump. 2005. Frankenthal, Germany: KSB Aktiengesellschaft.

SIRAWAN, Yudi. 2008. Sistem Pemipaan. Surabaya: Universitas Negeri Surabaya.

Published
2021-12-28
How to Cite
Rizki, M., Nalahuddin, M., & Muharni, R. (2021). Analisis Kebutuhan Debit Air Di Gedung C RSUD Kota Bukittinggi. Jurnal Teknik Mesin, 14(2), 94-98. https://doi.org/10.30630/jtm.14.2.657