Konsep Smart Building Pada Kenyamanan Termal di Laboratorium Teknik
Abstract
Engineering Laboratory is a place where students can learn the theory and then practicing of machines operate. Teaching room should be made as comfortabel as possible so can improve students. Room condition whereas there are practicum machines makes the room hotter.. Inadequate room capacity makes students uncomfortabel with the conditions of the practicum. The focus in this study is to examine the thermal comfort obtained by students, measurements of temperature and humidity. The method used to calculate the temperature index by calculating the Predicted Mean Vote Index (PMV), Predicted Dissatisfied (PPD), and Heat Stress Index (HSI). Result for This calculation is then used as a reference in the improvement analysis. The results obtained from the PMV calculation are 2.11 PPD 81.67%. This calculation used as a reference in the improvement analysis.
References
ASHRAE Handbook. 2005. Fundamentals, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, ASHRAE. 1989. Handbook of Fundamental Chapter 8: Physiological Principles, Comfort, and Health. ASHRAE. USA ISO 7730, 1984)
Lee et al. 2000 Indoor and outdoor air quality investigation at schools in Hong Kong. Chemosphere Jul;41(1-2):109-13.
Satwiko, Prasasto. 2004. Fisika Bangunan 1. Publisher Andi, Yogyakarta
Ariestadi, D. et al 2014, Energy Performance Criteria For Thermal Conditions In The Building Of High Education Facilities In Indonesia Analysis With Important Performance Analysis Method, Journal of RUAS, Vol. 12 No. 1, June 2014: ISSN 1693-3702
Priatman, Jimmy. 2003. Energy Conscious Design "Concept and Building Design Strategy in Indonesia. Journal of Architectural Dimension, Volume 31, Number 1, Department of Architecture FTSP Petra Christian University, Surabaya,
Kurnia, R., Effendy, S., Tursilowati, L. 2010. Identification of Building Thermal Comfort (Case Study: Classrooms in IPB Banangsiang and Darmaga Campuses), Journal of Agromet 24 (1), pp. 14-22, 2010, ISSN: 0126-3633, Bogor.
Rilatupa, James. 2008. Thermal Comfort Aspects of Space Conditioning, Journal of Gadgets Science and Technology, Vol. 18, No. 3, (Agustus 2008).
Rattanongphisata, W. et al, 2014 Strategy for energy efficient buildings in tropical climate, Energy Procedia 52, p 10 – 17
Susanti, L., dan Nike A. 2013. Thermal Leisure Evaluation of Public Senior High School Room In Padang City. (online),http://industri.ft.unand.ac.id/Pdf/josifiles/vol_12_no_1_april_2013 accessed 5 June 2013
Suma’mur P.K., 1996, Corporate Hygiene and Occupational Health. PT. Gunung Agung, Jakarta.
Kukus, Y, dkk, 2009, Suhu Tubuh: Homeostatis dan efek terhadap kinerja tubuh manusia. Jurnal Biomedik, Vol. 1 Nomor 2, hlm 107 - 118
Kotler, Phillip. 1995, Marketing Management Analysis, Planning, Implementation& Control. Prentice Hall Int
Irwanto. 2002. General Psychology. Jakarta: PT. Prenhallindo